Relationship between Preterm Delivery and Cervical Length Measurement in Second Trimester of Pregnancy at Chonburi Hospital

Authors

  • Natthanan Vilairuangchoovong Chonburi Hospital

Keywords:

Ultrasonography, cervical length measurement, preterm birth

Abstract

Objective: To determine the correlation of cervical length in the second trimester of pregnancy and preterm delivery at Chonburi hospital.

Materials and Methods: This is a retrospective cohort study of singleton pregnancy at the Obstetrics and Gynecology Department at Chonburi hospital. Cervical length was measured in pregnant women that underwent transvaginal ultrasound between 16-24 weeks of gestational age from 1 Mar 2017 to 30 June 2018. Fetal lethal anomaly, uterine anomaly, polyhydramnios, inadequate ultrasound and medically indicated preterm birth were excluded. Demographic, medical data such as gestational age at delivery, birth weight, and Apgar score were collected. The correlation between gestational age at delivery and cervical length was also evaluated.

Results: Three hundred and eighty-nine women with singleton pregnancies agreed to participate in the study. One hundred and six pregnancy (27.2%) were preterm delivery. Most pregnant women in this study were in the range of 20-35 years old (66.8%). Teenage pregnancy and advanced maternal age pregnancy were 16.2 percent and 17 percent, respectively. The normal body mass index was 32.6 percent. Underweight and obesity were 29.6 and 37.8 percent, respectively. Smoking history in pregnancy was 1.8 percent. Primigravidarum was 44.5 percent that was the most group. The prevalence of previous preterm delivery was 16.7 percent. The statistical significant risk factor with preterm birth was history of preterm birth. Transvaginal cervical length values were found to 19.0 mm in minimum value, 71.2 mm in maximum value and 40.2 mm in mean value. Cervical length was not correlated to less than 37 weeks of gestational age at delivery.

Conclusions: The second trimester cervical length was not correlated to preterm birth at Chonburi hospital.

Author Biography

Natthanan Vilairuangchoovong, Chonburi Hospital

Department of Obstetric and gynecolocy

References

Creasy RK RR, Iams JD, Lockwood CJ, Moore TR, Greene MF. Creasy and Resnik’s maternal-fetal medicine: principles and practice. 7th ed. Philadel-phia: Elsevier Sauder; 2014.

Beck S, Wojdyla D, Say L, Betran AP, Merialdi M, Requejo JH, et al. The worldwide incidence of preterm birth: a systematic review of maternal mortality and morbidity. Bulletin of the World Health Organization 2010;88:31-8.

Howson CP, Kinney MV, McDougall L, Lawn JE. Born too soon: preterm birth matters. Reproductive health 2013;10(1):1-14.

WHO ACTION Trials Collaborators. The World Health Organization ACTION-I (Antenatal CorTicosteroids for Improving Outcomes in pre-term Newborns) Trial: a multi-country, multi-centre, two-arm, parallel, double-blind, placebo-controlled, individually randomized trial of antenatal corticos-teroids for women at risk of imminent birth in the early preterm period in hospitals in low-resource countries. Trials 2019;20:1-11.

Walani SR. Global burden of preterm birth. In-ternational journal of gynecology & obstetrics 2020;150(1):31-3.

Voigt M, Briese V, Pietzner V, Kirchengast S, Sch-neider K, Straube S, et al. Evaluation of maternal parameters as risk factors for premature birth (individ-ual and combined effects). Zeitschrift fur Geburtshilfe und Neonatologie 2009;213(4):138-46.

Ahumada-Barrios ME, Alvarado GF. Risk factors for premature birth in a hospital. Revista latino-americana de enfermagem 2016;24:e2750. doi: 10.1590/1518-8345.0775.2750.

Williams JW. Preterm birth. In: Cunning FG LK, Leveno KJ, Bloom SL, Dashe JS, Hoffman BL, Casey BM, editors. Williams obstetrics. 25th ed. New York: McGraw-Hill; 2018. p. 803-914.

Crane J, Armson A, Brunner M, De S, Farine D, Keenan L, et al. Antenatal corticosteroid therapy for fetal maturation. Journal of obstetrics and gynaecol-ogy Canada 2003;25(1):45-52.

Crowther CA, Hiller JE, Doyle LW, Haslam RR. Effect of magnesium sulfate given for neuroprotection before preterm birth: a randomized controlled trial. Jama 2003;290(20):2669-76.

Groom KM, Bennett PR. Tocolysis for the treatment of preterm labour-a clinically based review. The Obstetrician & Gynaecologist 2004;6(1):4-11.

Direnzo GC, Roura LC, Facchinetti F, Antsaklis A, Breborowicz G, Gratacos E, et al. Guidelines for the management of spontaneous preterm labor: iden-tification of spontaneous preterm labor, diagnosis of preterm premature rupture of membranes, and preventive tools for preterm birth. The Journal of Maternal-Fetal & Neonatal Medicine 2011;24(5):659-67.

American College of Obstetricians and Gynecolo-gists; Committee on Practice Bulletins-Obstetrics. ACOG practice bulletin no. 127: management of preterm labor. Obstetrics and gynecology 2012;119(6):1308-17.

Grimes-Dennis J, Berghella V. Cervical length and prediction of preterm delivery. Current Opinion in obstetrics and gynecology 2007;19(2):191-5.

Valentin L, Bergelin I. Intra-and interobserver repro-ducibility of ultrasound measurements of cervical length and width in the second and third trimes-ters of pregnancy. Ultrasound in obstetrics and gynecology: The official journal of the international society of ultrasound in obstetrics and gynecology 2002;20(3):256-62.

Ressel G. ACOG releases bulletin on managing cervical insufficiency. American family physician 2004;69(2):436-9.

McIntosh J, Feltovich H, Berghella V, Manuck T. The role of routine cervical length screening in selected high-and low-risk women for preterm birth prevention. American journal of obstetrics and gynecology 2016;215(3):B2-7.

Crosby DA, Miletin J, Semberova J, Daly S. Is routine transvaginal cervical length measurement cost-effective in a population where the risk of spontaneous preterm birth is low? Acta obstetricia et gynecologica scandinavica 2016;95(12):1391-5.

Werner E, Han C, Pettker C, Buhimschi C, Copel J, Funai E, et al. Universal cervical-length screen-ing to prevent preterm birth: a cost-effectiveness analysis. Ultrasound in obstetrics & gynecology 2011;38(1):32-7.

Peixoto AB, Cunha Caldas TMRd, Alamy AHB, Martins WP, Bruns RF, Araujo Júnior E. Reference values for the cervical length measurement in the second trimester of pregnancy using the trans-vaginal ultrasound in a large Brazilian population. Obstetrics & gynecology science 2016;59(4):303-6.

Adams MM, Elam-Evans LD, Wilson HG, Gilbertz DA. Rates of and factors associated with recurrence of preterm delivery. The journal of the american medical association 2000;283(12):1591-6.

Silva SVL, Damião R, Fonseca EB, Garcia S, Lippi UG. Reference ranges for cervical length by transvaginal scan in singleton pregnancies. The journal of maternal-fetal & neonatal medicine 2010;23(5):379-82.

Jafari-Dehkordi E, Adibi A, Sirus M. Reference range of the weekly uterine cervical length at 8 to 38 weeks of gestation in the center of Iran. Advanced biomedical research 2015;4:115. doi: 10.4103/2277-9175.157839.

Guzman E, Walters C, Ananth C, O’Reilly-Green C, Benito C, Palermo A, et al. A comparison of sono-graphic cervical parameters in predicting spontane-ous preterm birth in high-risk singleton gestations. Ultrasound in Obstetrics and Gynecology: The official journal of the international society of ultrasound in obstetrics and gynecology 2001;18(3):204-10.

Berghella V, Saccone G. Cervical assessment by ultrasound for preventing preterm delivery. Cochrane database of systematic reviews 2019;9:1-46.

Downloads

Published

2021-08-25 — Updated on 2026-02-10

Versions