Quality Inspection of the Automated Sphygmomanometers in the Communities Surrounding Navamindradhiraj University

Authors

  • Suttida Hirun-aktawee Medical Instruments and Operating Room Technology, Faculty of Sciences and Health Technology, Navamindradhiraj University
  • Sunisa Chitratchata Medical Instruments and Operating Room Technology, Faculty of Sciences and Health Technology, Navamindradhiraj University
  • Areeya Jirathananuwat Department of Health Technology, Faculty of Sciences and Health Technology, Navamindradhiraj University, Thailand

Keywords:

quality inspection, automated sphygmomanometer, blood pressure, medical device

Abstract

The quality inspection of the automated sphygmomanometers in the communities surrounding the Navamindradhiraj University was using the BP Sure test. This test was from Department of Medical Sciences, Ministry of Public Health. The objective of the study was to inspect the quality control of the non-invasive blood pressure measurement devices as follow: (1) the document list of non-invasive automated blood pressure, (2) maximum permissible error of cuff pressure indication and air leakage, and (3) maximum permissible error of cuff pressure indication compared to the actual values of the person in case of inaccessible test mode. Of 42 machines were from community of Tha Nam Samsen, Rajphathapthimruamjai, and Navamindradhiraj. The results showed there were 25 machines (59.5%) passed both maximum permissible error and air leakage. Only one machine (2.5%) was not passed the qualify from damaged pin connector. Moreover, 16 machines were reported to unable to register test mode. Based on the findings of this study, non-invasive blood pressure should be inspected in more communities in order to observe quality of sphygmomanometers. After inspect services, they should evaluate the satisfaction of all recipients. Additionally, healthcare professions should encourage to train the BP sure test for further developing the standard inspection of blood pressure monitor service unit in the community.

Downloads

Download data is not yet available.

References

กลุ่มยุทธศาสตร์และแผนงาน สำนักโรคไม่ติดต่อ กรมควบคุมโรค. แผนยุทธศาสตร์การป้องกันและควบคุมโรคไม่ติดต่อระดับชาติ 5 ปี (พ.ศ. 2560-2564). กรุงเทพมหานคร: อิโมชั่นอาร์ต; 2560.

Rothwell PM, Howard SC, Dolan E, O’Brien E, Dobson JE, Dahlöf B, et al. Prognostic significance of vis¬it-to-visit variability, maximum systolic blood pressure, and episodic hypertension. Lancet 2010;375(9718):895- 905.

Webb AJ, Fischer U, Mehta Z, Rothwell PM. Effects of antihypertensive-drug class on interindividual variation in blood pressure and risk of stroke: a systematic review and meta-analysis. Lancet 2010;375(9718): 906-15.

Kearney PM, Whelton M, Reynolds K, Muntner P, Whelton PK, He J. Global burden of hypertension: anal¬ysis of worldwide data. Lancet 2005;365(9455):217- 23.

Aekplakorn W, Chariyalertsak S, Kessomboon P, As¬sanangkornchai S, Taneepanichskul S, Putwatana P. Prevalence of diabetes and relationship with socioeco¬nomic status in the Thai population: national health ex¬amination survey, 2004-2014. J Diabetes Res 2018; 2018:1654530.

Stergiou GS, Kario K, Kollias A, McManus RJ, Ohkubo T, Parati G, et al. Home blood pressure monitoring in the 21 stcentury.J Clin Hypertens (Greenwich) 2018; 20(7): 1116-21.

Breaux-Shropshire TL, Judd E, Vucovich LA, Shropshire TS, Singh S. Does home blood pressure monitoring im¬prove patient outcomes? A systematic review comparing home and ambulatory blood pressure monitoring on blood pressure control and patient outcomes. Integr Blood Press Control 2015;8:43-9.

STRIDE BP. Validated blood pressure monitors [Internet]. 2020 [cited 2022 Jan 20]. Available from: https:// www.stridebp.org/.

Picone DS, Deshpande RA, Schultz MG, Fonseca R, Campbell NRC, Delles C, et al. Nonvalidated home blood pressure devices dominate the online marketplace in Australia: major implications for cardiovascular risk management. Hypertension 2020;75(6):1593-99.

มติชนออนไลน์. สธ. สุ่มตรวจเครื่องวัดความดันโลหิตทั่วประเทศ พบตกมาตรฐาน19%ส่งผลต่อการวินิจฉัยแพทย์ [อินเทอร์เน็ต]. 2562 [สืบค้นเมื่อ30 ม.ค. 2565]. แหล่ง ข้อมูล: https://www.matichon.co.th/news-monitor/ news_1743530.

กรมวิทยาศาสตร์การแพทย์ กระทรวงสาธารณสุข. กรมวิทย์ฯ พัฒนาเครื่องทดสอบเครื่องวัดความดันโลหิต BP Sure ให้เจ้าหน้าที่สาธารณสุข อสม. และประชาชนตรวจสอบเครื่องวัดความดันโลหิตในพื้นที่ได้เอง [อินเทอร์เน็ต]. 2562 [สืบค้นเมื่อ26 ม.ค. 2565]. แหล่งข้อมูล: https://www3.dmsc.moph.go.th/post-view/584

ECRI, Instructions of preventive maintenance, procedure No. 454-20160810 for sphygmomanometers (aneroid or mercury); 2016. Plymouth Meeting, PA: ECRI; 2016.

The international Organization of Legal Metrology. Non-invasuve automated sphygmomanometers [Internet]. 2002 [cited 2022 Apr 8]. Available from: https://www. oiml.org/en/files/pdf_r/r016-2-e02.pdf

กรมวิทยาศาสตร์การแพทย์ กระทรวงสาธารณสุข. การทดสอบเครื่องวัดความดันโลหิตด้วยแอปพลิเคชัน BP Sure [อินเทอร์เน็ต]. [สืบค้นเมื่อ 26 ม.ค. 2565]. แหล่งข้อมูล: http://rmsc8.dmsc.moph.go.th/CMS/วิชาที่ 1.2 การทดสอบเครื่องวัดความดันโลหิต.pdf

รักหมอ เมดิคอล. มาตรฐานเครื่องวัดความดัน ควรเป็นแบบไหนดี เลือกซื้ออย่างไรดีให้ได้คุณภาพ วัดค่าได้แม่นยำ[อินเทอร์เน็ต]. 2564 [สืบค้นเมื่อ 27 มิ .ย. 2565]. แหล่งข้อมูล: https://rakmor.com/standard-pressure-gauge/

ธีรเดช ภัทรวโรดม, เกศสุดา สืบสังข์, รามิล กาญจนสดุ้ง. การศึกษาค่าความผิดพลาดของเครื่องวัดความดันโลหิตแบบอิเล็กทรอนิกส์เปรียบเทียบกับเครื่องมือมาตรฐาน [อินเทอร์เน็ต]. 2557 [สืบค้นเมื่อ4 มิ .ย. 2565]. แหล่งข้อมูล: https://hss.moph.go.th/fileupload_doc/2015- 10-18-15646077.pdf

de Greeff A, Lorde I, Wilton A, Seed P, Coleman AJ, Shennan AH. Calibration accuracy of hospital-based non-invasive blood pressure measuring devices. J Hum Hypertens 2010;24(1):58-63.

Published

2024-08-31

How to Cite

หิรัญเอกทวี ส., ชิตรัชตะ ส., & จิรธนานุวัฒน์ อ. (2024). Quality Inspection of the Automated Sphygmomanometers in the Communities Surrounding Navamindradhiraj University . Journal of Health Science of Thailand, 33(4), 767–776. Retrieved from https://thaidj.org/index.php/JHS/article/view/12812

Issue

Section

Original Article (นิพนธ์ต้นฉบับ)