The Initial cuff inflation volume for 7.0 and 7.5 mm endotracheal tubes to achieve a cuff pressure of 20-30 cmH₂O in adults undergoing general anesthesia at Chaiyaphum Hospital: a prospective repeated-measures study

-

Authors

  • Dalad Phromphan Anesthesiologist, Professional Level, Anesthesiology Department, Chaiyaphum Hospital
  • Bundharika Artnasiaw Anesthesiologist, Senior Professional Level, Anesthesiology Department, Chaiyaphum Hospital
  • Sirinat Suwannamagkorn Nurse anesthetist, Professional Level, Anesthesiology Department, Chaiyaphum Hospital

Keywords:

cuff, cuff pressure, cuff inflation volume, endotracheal tube, general anesthesia

Abstract

            Endotracheal tube cuff pressure should be 20-30 cmH₂O, but pilot balloon palpation is inaccurate, and Thai data on initial inflation volumes by tube size are limited. This study aimed to determine the initial air volume yielding the highest proportion of target pressure for 7.0 and 7.5 mm tubes. In this prospective repeated measures study at Chaiyaphum Hospital, 75 adults under general anesthesia (45 women, 7.0 mm tubes; 30 men, 7.5-mm tubes) had cuffs inflated with 3-8 mL of air, with pressure measured by cuff manometer at each volume. Success proportions with 95% confidence intervals were analyzed using GEE with restricted cubic splines.

            Among 450 measurements, success was highest at 4 mL for 7.0 mm tubes (53.3%; 95% CI 39.1, 67.1; 20.0% below, 26.7% above target) and at 5 mL for 7.5 mm tubes (50.0%; 95% CI 33.2, 66.8; 16.7% below, 33.3% above). Larger volumes sharply increased overinflation, reaching 93.3% at 6 mL with 7.0 mm tubes. Spline models showed an inverted U pattern peaking at 3.6 and 5.1 mL, respectively.

            Initial volumes of 4 mL (7.0 mm tubes, women) and 5 mL (7.5 mm tubes, men) are reasonable starting points, but as nearly half of patients remained outside the target range, cuff pressure should be verified and adjusted with a cuff manometer.

References

Seegobin RD, van Hasselt GL. Endotracheal cuff pressure and tracheal mucosal blood flow: endoscopic study of effects of four large volume cuffs. Br Med J (Clin Res Ed) 1984;288(6422):965-8. DOI:10.1136/bmj.288.6422.965

Turner MA, Feeney M, Deeds LJL. Improving endotracheal cuff inflation pressures: an evidence-based project in a military medical center. AANA J 2020;88(3):203-8. PMID:32442097

Sultan P, Carvalho B, Rose BO, Cregg R. Endotracheal tube cuff pressure monitoring: a review of the evidence. J Perioper Pract 2011;21(11):379-86. DOI:10.1177/175045891102101103

Gilliland L, Perrie H, Scribante J. Endotracheal tube cuff pressures in adult patients undergoing general anaesthesia in two Johannesburg academic hospitals. S Afr J Anaesth Analg 2015;21(3):35-8. DOI:10.1080/22201181.2015.1056504

Sengupta P, Sessler DI, Maglinger P, Wells S, Vogt A, Durrani J, et al. Endotracheal tube cuff pressure in three hospitals, and the volume required to produce an appropriate cuff pressure. BMC Anesthesiol 2004;4(1):8. DOI:10.1186/1471-2253-4-8

Rouze A, Jaillette E, Nseir S. Continuous control of tracheal cuff pressure: an effective measure to prevent ventilator-associated pneumonia?. Crit Care 2014;18(5):512. DOI:10.1186/s13054-014-0512-2

Coppadoro A, Bellani G, Foti G. Non-Pharmacological Interventions to Prevent Ventilator-Associated Pneumonia: A Literature Review. Respir Care 2019;64(12):1586-95. DOI:10.4187/respcare.07127

Feng TR, Ye Y, Doyle DJ. Critical importance of tracheal tube cuff pressure management. World J Anesthesiol 2015;4(2):10-2. DOI:10.5313/wja.v4.i2.10

Mu G, Wang F, Li Q, Yu X, Lu B. Reevaluating 30 cmH2O endotracheal tube cuff pressure: risks of airway mucosal damage during prolonged mechanical ventilation. Front Med (Lausanne) 2024;11:1468310. DOI:10.3389/fmed.2024. 1468310

Zhu G, Wang X, Cao X, Yang C, Wang B, Ang Y, et al. The effect of different endotracheal tube cuff pressure monitoring systems on postoperative sore throat in patients undergoing tracheal intubation: a randomized clinical trial. BMC Anesthesiol 2024;24(1):115. DOI:10.1186/s12871-024-02499-5

Wang C, Yan X, Gao C, Liu S, Bao D, Zhang D, et al. Effect of continuous measurement and adjustment of endotracheal tube cuff pressure on postoperative sore throat in patients undergoing gynecological laparoscopic surgery: a randomized controlled trial. J Clin Monit Comput 2024;38(6):1379-86. DOI:10.1007/s10877-024-01173-y

Sadovyi V, Kuchyn I, Bielka K, Horoshko V, Sazhyn D, Sokolova L. Endotracheal tube cuff pressure assessment: expectations versus reality. Anaesthesiol Intensive Ther 2024;56(4):241-5. DOI:10.5114/ait.2024.145411

Rahmani F, Soleimanpour H, Zeynali A, Mahmoodpoor A, Shahsavari Nia K, Rahimi Panahi J, et al. Comparison of tracheal tube cuff pressure with two techniques: fixed volume versus pilot balloon palpation. J Cardiovasc Thorac Res 2017;9(4):196-9. DOI:10.15171/jcvtr.2017.34

Kumar CM, Seet E, Van Zundert TCRV. Measuring endotracheal tube intracuff pressure: no room for complacency. J Clin Monit Comput 2021;35(1):3-10. DOI:10.1007/s10877-020-00501-2

Ammaraporn S, Mamaethong T, Chaiyoslap K, Khrukaew T. Comparison of endotracheal tube cuff pressure with passive release technique for cuff inflation between disposable and loss of resistance syringe in patients undergoing general anesthesia. Thai J Anesthesiol 2024;50(4):231-40. https://he02.tci-thaijo.org/index.php/anesthai/ article/view/269958

Shibasaki M, Nakajima Y, Shime N, Sawa T, Sessler D I. Prediction of optimal endotracheal tube cuff volume from tracheal diameter and from patient height and age: a prospective cohort trial. Journal of Anesthesia 2012;26(4):536-40. DOI:10.1007/s00540-012-1371-0

Von Elm E, Altman DG, Egger M, Pocock SJ, Gøtzsche PC, Vandenbroucke JP. The Strengthening the Reporting of Observational Studies in Epidemiology (STROBE) statement: guidelines for reporting observational studies. Lancet 2007;370(9596):1453-7. DOI:10.1016/S0140-6736(07)61602-X

Peduzzi P, Concato J, Kemper E, Holford TR, Feinstein AR. A simulation study of the number of events per variable in logistic regression analysis. J Clin Epidemiol 1996;49(12):1373-9. DOI:10.1016/s0895-4356(96)00236-3

Liang KY, Zeger SL. Longitudinal data analysis using generalized linear models. Biometrika 1986;73(1):13-22. DOI:10.1093/biomet/73.1.13

Desquilbet L, Mariotti F. Dose-response analyses using restricted cubic spline functions in public health research. Stat Med 2010;29(9):1037-57. DOI:10.1002/sim.3841

Willis BA, Latto IP, Dyson A. Tracheal tube cuff pressure. Clinical use of the Cardiff cuff controller. Anaesthesia 1988;43(4):312-4. DOI:10.1111/j.1365-2044.1988.tb08983.x

Wu HL, Wu YH, Shen WQ, Shi JH, Xu YH, Shen HW, et al. Relationship between difference in endotracheal tube cuff area and airway area with minimum cuff pressure for adequate airway sealing: a prospective observational study. Sci Rep 2025;15(1):5875. DOI:10.1038/s41598-025-85355-x

Published